Overview
Quick Details
Place of Origin:
Beijing, China (Mainland)
Brand Name:
ZBL
Model Number:
ZBL-P8000
Packaging & Delivery
Packaging Details
CARTON
Delivery Time
10days

 

Field of use

By using the reflected wave method, the apparatus is used to assess the integrality of concrete pile and identify the extent and location of the pile defect. It can be used for testing perfusion pile and hammer pile. It can also be used for testing the exposed top surface of constructions such as pillars.

Features

    Intelligent sensor can complete the acquisition work alonely, and upload the data to the computer through the WiFi , get rid of signal wireentanglement, efficient, fast and smooth;

    True 24 bit A/D data acquisition, the test waveform is more real, to avoid the noise and signal distortion caused by large floating point  amplification;

    The real-time analysis of detected waves, a new wavelet analysis in complex situations can be more accurate to judge pile integrity

    intelligent upgrade detection software in the PAD Online.

 

Technical specifications

 

 

Item

Specifications

Model

ZBL-P8100

ZBL-P8000

Control Mode

A8 Embedded platform

see parameters of PAD

Screen

5.7inch,High brightness, TFT color LCD screen

Data Storage

≥4GB

Operation Mode

key+touch screen

Sentinel magnify (time)

1,2,5,10,20,50,100 adjustable

1,2,4,8,16,32 adjustable

A/D resolution (bit)

true 24 bits A/D

true 24 bits

Sampling time intervals(μs)

1~64000 adjustable

6.4~204.8 adjustable

Max length of sampling

4096

2048

Trigger

Signal trigger,

Signal trigger,

Noise voltage of the system (mV)

≤1

≤2

Dynamic range(dB)

 ≥184

160

Amplifier frequency range(Hz)

10~10k

1~20k

Max storage length

4096

2048

Amplitude nonlinear degree

≤10%

Time value error

≤1%

Time resolving power(us)

1

6.4

Gain error(dB)

≤1

Continuous working time(h)

>5

>6

Number of channels

2

1

Interference between the channels

≤1%

none

Transducer/Probe Sensitivity

(acceleration mode)(mv/g)

≥100

Frequency range of Probe

(Acceleration probe) (Hz)

0.5 ~ 9000

Transmission port

double USB

see parameters of PAD

Wi-fi

yes

Power

Built-in

battery

Outside

220V AC/DC

Weight(kg)

1.3(lithium battery included)

0.34kg(lithium battery included)

Size(mm)

210×149×60

φ50×120

Operational

evvironment

Temperature(℃)

-10 ~+50

0 ~+40

Humidity(RH)

< 90%